An ex vivo comparison of bond strength measured by the push-outtest between AH Plus and Endosequence BC sealer Hiflow

Authors

DOI:

https://doi.org/10.54589/aol.38/3/210

Keywords:

Dentine, Push-Out Bond Strength

Abstract

Endodontic obturation is fundamental to treatment success, with the bond strength of sealer cements to dentin being a crucial parameter for evaluating their effectiveness. Aim: To evaluate the bond strength between root canal dentin walls and the obturation materials AH Plus and Endosequence BC Sealer HiFlow using the push-out test. Material and Method: Twenty single-rooted mandibular premolars were divided into two groups (n=10) according to the sealer used: Group AH (AH Plus Sealer) and Group HF (Endosequence BC Sealer HiFlow). The canals were instrumented with Wave One Gold Large, using 20 mL of 2.5% sodium hypochlorite as irrigation solution. The teeth were cut into 1 mm thick slices in the cervical and middle third regions to perform the push-out test. The failure mode was observed under a stereomicroscope at 40x magnification. The results were subjected to Tukey’s test and ANOVA with a 5% significance level. Results: In the push-out bond strength test, there was no statistically significant difference between AH Plus and Endosequence BC Sealer HiFlow cements (p=0.1952). Similarly, the failure modes showed no significant difference between the cements, in both the cervical and middle thirds (p=0.5703). Conclusion: AH Plus and Endosequence BC Sealer HiFlow demonstrated similar behavior in terms of bond strength and failure mode in root canal dentin walls.

Downloads

Download data is not yet available.

Author Biographies

  • Marilia F V Marceliano-Alves, Universidade Iguaçu, Programa de Pós-Graduação em Odontologia, Nova Iguaçu, Brasil

    Universidade Iguaçu, Programa de Pós-Graduação em Odontologia, Nova Iguaçu, Brasil

    Centro Universitário Maurício de Nassau, Rio de Janeiro, Brasil

    Department of Dental Research Cell, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Pune 411018, India

  • Cesar AP Rosas, Universidade Estadual do Norte do Paraná, Campus de Jacarezinho, Paraná, Brasil

    State University of Northern Paraná, Jacarezinho Campus, Paraná, Brazil

Downloads

Published

2025-12-31

Issue

Section

Artículos originales

How to Cite

An ex vivo comparison of bond strength measured by the push-outtest between AH Plus and Endosequence BC sealer Hiflow. (2025). Acta Odontológica Latinoamericana, 38(3), 210-215. https://doi.org/10.54589/aol.38/3/210